English
Metric
My Cart

Vacuum Gauges

Vacuum gauges are measurement components on vacuum systems and enable pressure measurement in specific ranges by operating compatibles controllers.

Diaphragm Gauge, temperature compensated, set points | 400593
Connection type
CF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
230 °F
Relais count
2
Interface type
Analogue, RS232
Purity class
PCS
Connection type
CF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
110 °C
Relais count
2
Interface type
Analogue, RS232
Purity class
PCS
Please login to see prices.
on request
Diaphragm Gauge, temperature compensated, set points | 400597
Connection type
KF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
230 °F
Relais count
2
Interface type
Analogue, RS232
Purity class
PCS
Connection type
KF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
110 °C
Relais count
2
Interface type
Analogue, RS232
Purity class
PCS
Please login to see prices.
available
Diaphragm Gauge, temperature controlled | 407400
Connection type
CF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
230 °F
Interface type
RS232, Analogue
Relais count
2
Purity class
PCS
Connection type
CF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
110 °C
Interface type
RS232, Analogue
Relais count
2
Purity class
PCS
Please login to see prices.
on request
Diaphragm Gauge, temperature controlled | 407405
Connection type
KF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
230 °F
Interface type
RS232, Analogue
Relais count
2
Purity class
PCS
Connection type
KF
Nominal diameter
16
Pressure range
1.3E-2 - 133 mbar
Principle of measurement
Diaphragm (capacitive)
Bakeout temperature
110 °C
Interface type
RS232, Analogue
Relais count
2
Purity class
PCS
Please login to see prices.
on request
Active Pirani-Gauge, no set points | 400801
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
176 °F
Interface type
Analogue
Purity class
PCS
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
80 °C
Interface type
Analogue
Purity class
PCS
Please login to see prices.
available
Active Pirani-Gauge, no set points | 400802
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
482 °F
Interface type
Analogue
Purity class
PCS
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
250 °C
Interface type
Analogue
Purity class
PCS
Please login to see prices.
on request
Active Pirani-Gauge, no set points | 400800
Connection type
KF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
176 °F
Interface type
Analogue
Purity class
PCS
Connection type
KF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
80 °C
Interface type
Analogue
Purity class
PCS
Please login to see prices.
available
Active Pirani-Gauge, set points | 400805
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
176 °F
Interface type
Analogue
Relais count
2
Purity class
PCS
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
80 °C
Interface type
Analogue
Relais count
2
Purity class
PCS
Please login to see prices.
on request
Active Pirani-Gauge, set points | 403031
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
176 °F
Interface type
Analogue
Relais count
2
Purity class
PCS
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
80 °C
Interface type
Analogue
Relais count
2
Purity class
PCS
Please login to see prices.
on request
Active Pirani-Gauge, set points | 400806
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
482 °F
Interface type
Analogue
Relais count
2
Purity class
PCS
Connection type
CF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
250 °C
Interface type
Analogue
Relais count
2
Purity class
PCS
Please login to see prices.
on request
Active Pirani-Gauge, set points | 400804
Connection type
KF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
176 °F
Interface type
Analogue
Relais count
2
Purity class
PCS
Connection type
KF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
80 °C
Interface type
Analogue
Relais count
2
Purity class
PCS
Please login to see prices.
on request
Active Pirani-Gauge, set points | 404734
Connection type
KF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
176 °F
Interface type
Analogue
Relais count
2
Purity class
PCS
Connection type
KF
Nominal diameter
16
Pressure range
5E-4 - 1000 mbar
Principle of measurement
Pirani, Thermal conductivity
Bakeout temperature
80 °C
Interface type
Analogue
Relais count
2
Purity class
PCS
Please login to see prices.
on request
You have not found a suitable product for your application?

We will be happy to advise you on further vacuum measurement technologies that are currently not available in our shop.